Product filters

Made in Udmurtia
Price

 – 

  • 0
  • 1057600

Electrical Equipment, Components & Telecoms

253 638.00 

Features of the Stalker 75-24 locator (built-in GPS/GLONASS module, Li-Ion)

  • “Compass” function - schematic display of two communications on the receiver display;
  • search for the position of transmitting probes and television inspection cameras
  • tracking and coordinating location in a worldwide coordinate system;
  • built-in GPS/GLONASS module
  • high-precision positioning (up to 1 cm) together with GPS RTK – PrinCe LT700H tablet;
  • the ability to use a smartphone instead of an external GPS/GLONASS module;
  • communication with a computer via Bluetooth, memory for 10,000 measurements;
  • for gas services, ECP frequencies are separately allocated for operation without a generator;
  • the Stalker 75-24 locator will automatically display the depth and current strength (even in passive modes);
  • search for communications at a depth of up to 10 m and a distance of up to 10 km from the generator connection point;
  • the presence of four operating frequencies and adjustable output power of the GT-75 generator (from 10 to 75 W). This generator is included in the set of Stalker defect detection systems: 75-14, 75-04, 75-02M;
  • the PT-24 receiver menu is in Russian, English and Chinese.
In stock
+

185 745.00 

The "Stalker 75-12" route finder is designed to determine the planned position and depth of communications, and survey areas of the area before carrying out excavation work.

The delivery package for the Stalker 75-12 locator includes a GT-75 generator and a PT-12 receiver.

General features of the Stalker 75-12 locator:

  • A simple and understandable process for searching for underground communications;
  • Search range - up to 10 km at a depth of up to 6 m;
  • “RADIO” frequency (passive) for searching a route without a generator;
  • Non-contact transmission of a search signal using transmitting clamps KI-50.
In stock
+

46 939.50 

The device is designed to test residual current devices (RCDs) of AC, A, B types. The RCD type and its rated differential current are set manually in the device. All types of RCDs that do not have an operational amplifier with threshold values can be checked using the device offline, for example, when buying, without connecting voltage to the mains. There is a function for measuring the resistance of the phase-zero loop from 0.4 to 60 ohms. PZO-510 is equipped with magnetic holders, which allows, if necessary, to quickly mount the device on steel surfaces, including those with paint and varnish coatings.

The instrument is powered by a NI-MH 6 V 2A/H battery or five 1.5 V AA batteries.

Operating temperature range from -15 to +55 0C.

Calibration interval 2 years.

In stock
+

244 183.00 

The "Stalker 80-12" route finder is designed to determine the planned position and depth of communications, and survey areas of the area before carrying out excavation work.

The delivery package for the Stalker 80-12 locator includes a GT-80 generator and a PT-12 receiver. The principles of working with locators of the “Stalker” series can be found in educational films:

General features of the Stalker 80-12 locator:
  • A simple and understandable process for searching for underground communications;
  • Remote control of the GT-80 generator via the GSM network;
  • 33 kHz frequency for contactless transmission of the generator signal into communication
  • Search range - up to 10 km at a depth of up to 6
  • “RADIO” frequency (passive) for searching a route without a generator;
  • Non-contact transmission of a search signal using transmitting clamps KI-50 or KI-100.
In stock
+

12 500.00 

Bactericidal recirculator IzhZdrav closed-type device for air purification and disinfection.

Decontamination efficiency up to 99.9%. The purifier is effective against all viruses, including influenza, rotavirus, smallpox, rabies, tuberculosis, ebola, SARS and others. In addition, spores of fungi, bacteria, mold and other microorganisms are destroyed.

It is intended for use in categories 4 and 5 of the list of premises of medical institutions and in categories 1-4 of the list of food industry enterprises providing the required level of bactericidal efficacy (%) and volumetric dose Hv (J / m³) for the sanitary indicative microorganism Staphylococcus Aureus. It is possible to use the device in the presence of people and animals.

In stock
+

Minimum quantity for "Bactericidal recirculator IzhZdrav" is 1.


101 565.00 

Measurement of the resistance of grounding elements, metal connections, continuity of protective conductors using a two-, three- or four-wire method.

Measurement of soil resistivity.

Measuring the resistance of a single grounding conductor in a multi-element grounding system without disconnecting it using measuring clamps (KTI-20/1 or KTI-20/2).

Measurement of the resistance of grounding elements without the use of auxiliary electrodes (GOST R 50571.16) using two clamps (KP-20/1 and KTI-20/1 or KP-20/1 and KTI-20/2).

AC current measurement without breaking the circuit.

Measurement of AC voltage (noise).

In stock
+

293 440.50 

The route finder "Stalker 80-14" (Li-Ion) is designed to determine the planned position and depth of communications, places of damage to the insulation of pipelines and cables with further cartographic analysis.

The delivery package for the Stalker 80-14 locator includes a GT-80 generator and a PT-14 receiver (Li-Ion)

The principles of operation of the Stalker series locators with high-precision GPS RTK tablet PrinCe LT700H can be found in the training film https://youtu.be/ixbdZwx_-n8

General features of the Stalker 80-14 locator:

  • “Compass” function - schematic display of communications on the receiver display;
  • tracking and coordinating location in a worldwide coordinate system;
  • communication with a computer via Bluetooth, memory for 10,000 measurements;
  • High-precision positioning (up to 1 cm) together with GPS RTK – PrinCe LT700H tablet;
  • the ability to use a smartphone instead of an external GPS/GLONASS module;
  • for gas services, ECP frequencies are separately allocated for operation without a generator;
  • the Stalker 80-14 locator will automatically display the depth and current strength (even in passive modes);
  • remote control of the generator via the GSM network;
  • frequency 33 kHz for contactless supply of the generator signal to communication;
  • search for communications at a depth of up to 10 m and a distance of up to 10 km from the generator connection point;
  • the presence of five operating frequencies and adjustable output power of the GT-80 generator (from 10 to 80 W). This generator is included in the set of Stalker defect detection systems: 80-24, 80-14, 80-12;
  • PT-14 receiver menu in Russian and English.
In stock
+

223 504.00 

The Stalker 75-14 route finder is designed to determine the planned position and depth of communications, places of damage to the insulation of pipelines and cables with further cartographic analysis.

The delivery package for the Stalker 75-14 locator includes a GT-75 generator and a PT-14 receiver with a built-in GPS/GLONASS module (Li-Ion)

The principles of operation of the Stalker series locators with high-precision GPS RTK tablet PrinCe LT700H can be found in the training film https://youtu.be/ixbdZwx_-n8

General features of the Stalker 75-14 locator:

  • “Compass” function - schematic display of communications on the receiver display;
  • tracking and coordinating location in a worldwide coordinate system;
  • communication with a computer via Bluetooth, memory for 10,000 measurements;
  • built-in GPS/GLONASS module;
  • High-precision positioning (up to 1 cm) together with GPS RTK – PrinCe LT700H tablet;
  • the ability to use a smartphone instead of an external GPS/GLONASS module for gas services, ECP frequencies are separately allocated for operation without a generator;
  • the Stalker 80-14 locator will automatically display the depth and current strength (even in passive modes);
  • remote control of the generator via the GSM network;
  • frequency 33 kHz for contactless supply of the generator signal to communication;
  • search for communications at a depth of up to 10 m and a distance of up to 10 km from the generator connection point;
  • the presence of five operating frequencies and adjustable output power of the GT-75 generator (from 10 to 75 W). This generator is included in the set of Stalker defect detection systems: 75-24, 75-14, 75-12;
  • PT-14 receiver menu in Russian and English.
In stock
+

175 131.00 

Locator "Stalker 15-14" - fast and accurate search for telephone, power cables and other communications, identification of coating defects and depth, followed by mapping.

The delivery package for the Stalker 15-14 locator includes a GT-15 generator and a PT-14 receiver (Li-Ion).

In stock
+

127 490.00 

Measurement of the resistance of grounding elements, metal connections, continuity of protective conductors using a two-, three- or four-wire method.

Measurement of soil resistivity.

Measuring the resistance of a single grounding conductor in a multi-element grounding system without disconnecting it using measuring clamps (KTI-20/1 or KTI-20/2).

Measurement of the resistance of grounding elements without the use of auxiliary electrodes (GOST R 50571.16) using two clamps (KP-20/1 and KTI-20/1 or KP-20/1 and KTI-20/2).

AC current measurement without breaking the circuit.

Measurement of AC voltage (noise).

In stock
+

Contact us for a price
The operation of the wattmeter is based on the principle of converting the power of high-frequency/microwave signals into thermal energy with subsequent...
In stock

68 310.00 
The B5-107 DC pulse power supply is designed to reproduce the output stabilized voltage and current with wide adjustment limits when used for the...
In stock
+

118 083.80 

State register number 62558-15, ссылка на сайт.

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

In stock
+

36 300.00 
Multifunctional portable digital measuring device designed for diagnostics of insulation condition. The megohmmeter allows you to measure insulation...
In stock
+

153 213.70 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

In stock
+

108 598.30 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

In stock
+

83 063.70 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

In stock
+

277 123.00 

The PM-3 marker detector is designed to detect all types of passive electronic markers (including intelligent ones) used to identify underground communications.

The PM-3 marker detector allows you to record and read data from intelligent electronic markers of the 1400‑XR‑iD, 1200‑XR‑iD series.

You can get acquainted with the function of recording smart markers by following the link https://youtu.be/DgzZ-1EksYo

Peculiarities:

  • Determining the position of eight types of electronic markers:

1. Cable TV,
2. Gas supply,
3. FOCL,
4. Telephone communications,
5. Sewerage,
6. Water pipes,
7. Electricity supply,

8. Process water (general purpose);

  • Scan mode: search simultaneously for up to four markers of various types;
  • Determining the depth of the marker (depending on the type of marker up to 3.0 m);
  • Memory for 10,000 points, wireless communication with PC;
  • The ability to record readings linked to coordinates received from an external GPS/GLONASS module and subsequently transmit them for viewing on a computer or device with Android OS.
  • High-precision positioning (up to 1 cm) together with GPS RTK – PrinCe LT700H tablet;
  • Possibility of using a smartphone instead of an external GPS/GLONASS module
In stock
+

194 254.50 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

In stock
+

49 000.00 
B5 - 71 KIP is a laboratory DC power supply. The device is designed to supply radio and electrical devices with standardized characteristics,...
In stock
+

95 831.00 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

In stock
+

155 428.00 

The PM-2 marker detector is designed to detect all types of passive electronic markers (including intelligent ones) used to identify underground communications.

Peculiarities:

Determination of the position of eight types of electronic markers:

  • Cable TV,
  • Gas supply,
  • FOCL,
  • Telephone communications,
  • Sewerage,
  • Water pipes,
  • Electricity supply,
  • Process water (general purpose);
  • Scan mode: search simultaneously for up to four markers of various types;
  • Determining the depth of the marker (depending on the type of marker up to 3.0 m);
  • Memory for 10,000 points, wireless communication with PC;
  • High-precision positioning (up to 1 cm) together with GPS RTK – PrinCe LT700H tablet;
  • Possibility of using a smartphone instead of an external GPS/GLONASS module
In stock
+

1 708.00 

Ball, self-leveling markers of the MP series are made in Russia.

Electronic markers are designed to mark the location of underground communications and are detected using Stalker marker detectors, as well as all types of marker detectors that have the appropriate search frequencies.

Detection depth: typical up to 1.6 m, maximum 1.8 m.

Operating temperature range from minus 30 to plus 55 ºС

External pressure, no more than 75 kPa

Estimated service life is 50 years.

The diameter of the sphere is no more than 110 mm, weight no more than 0.23 kg.

In stock
+

70 296.40 

The volt-ampere phase meter RS-30 is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current-measuring clamps is performed using a quick-release Push-Pull connection. The volt-ampere phase meter RS-30 is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

In stock
+