No items found matching the search criteria
₽ – ₽
PTE5000C-010G 1/2-C Pressure sensor 0.10 bar, accuracy 0.5%, output 4.20 mA, G1/2 male thread, power supply 10.30 V DC, -20..+100 deg C
Minimum quantity for "PTE5000C-010-G1/2-C" is 1.
Minimum quantity for "PNA-DA-105" is 1.
State register number 62558-15, link to the website
The calibration interval is 24 months.
The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.
EMD-MINI – 015 S ELHART frequency converter (1.5 kW, 7 A, 220 V, built-in PID controller, 4 discrete inputs (NPN), 1 discrete output (NO relay, 250 V, 3 A), 1 analog input 4-20 mA / 0-10 V, rotary frequency converter, RS-485 Modbus RTU, DIN rail mounting), EMD-MINI series
Minimum quantity for "EMD-MINI – 015 T" is 1.
Minimum quantity for "PNA-DA-190" is 1.
1901R-KDPA100-012-24DC Direct acting solenoid valve, brass, 1/8” (1.2 mm), 2/2 NC, -10°C...+160°C, 0...100 bar, 24VDC, PTFE seals
Minimum quantity for "1901R-KDPA100-012-24DC" is 1.
1901R-ABNF016-250-220AC Solenoid valve, brass, 1" (25 mm), 2/2 NO, -10°C...+80°C; 0.5...16 bar,floating membrane design, coil with moisture protection (coil type 4)
Minimum quantity for "1901R-ABNF016-250-220AC" is 1.
Minimum quantity for "PIV-S-E-14.24DC" is 1.
PTE5000C-006-G1/4-C 0.6bar pressure sensor, 0.5% accuracy, 4.20 mA output, G1/4 male thread, 10.30 VDC power supply
Minimum quantity for "PTE5000C-006-G1/4-C" is 1.
Minimum quantity for "EMD-MINI – 022 T" is 1.
Minimum quantity for "PNA-DA-063" is 1.
Minimum quantity for "PIV-S-B-14.24AC" is 1.
1901R-ABND016-120-220AC brass, 1/2" (12 mm), 2/2 NO, -10°C...+80°C; 0.5...16 bar, 220V 50-60Hz, floating membrane design, coil with moisture protection (coil type 4)
Minimum quantity for "1901R-ABND016-120-220AC" is 1.
1901R-KBNE016-190-24DC Solenoid valve, brass, 3/4" (19 mm), 2/2 NC, -10°C...+80°C; 0.5...12 bar, 24 V DC, floating membrane design, coil with moisture protection (coil type 1, spare parts type A)
Minimum quantity for "1901R-KBNE016-190-24DC" is 1.
1901R-KBND016-120-220AC Solenoid valve, brass, 1/2" (12 mm), 2/2 NC, -10°C...+80°C; 0.5...16 bar, , floating membrane design, coil with moisture protection (coil type 1, spare parts type A)
ASV-T-050-AL080-U Valve with pneumatic actuator, stainless steel, threaded 2/2 NC, G 2'' (DN 50), T=(-10...+180)C, Punder disk=(0…8 bar), pneumatic actuator 80 mm single-acting (port 1/4'')
Minimum quantity for "ASV-T-050-AL080-U" is 1.
1901R-KBNE016-190-220AC Solenoid valve, brass, 3/4" (19 mm), 2/2 NC, -10°C...+80°C; 0.5...16 bar, 220V 50-60Hz, floating membrane design, coil with moisture protection (coil type 1, spare parts type A)
Minimum quantity for "1901R-KBNE016-190-220AC" is 1.
Minimum quantity for "PIV-S-B-14.24DC" is 1.
Minimum quantity for "PIV-S-A-14.24DC" is 1.
PIV-S-AP-18 Pneumatic distribution valve 5/2, G 1/8'', 1.5...8 bar
Minimum quantity for "PIV-S-AP-18" is 1.