Product filters

Made in Udmurtia
Price

 – 

  • 0
  • 256020

Instrumentation

197 940.00 

The "Stalker 80-12" route finder is designed to determine the planned position and depth of communications, and survey areas of the area before carrying out excavation work.

The delivery package for the Stalker 80-12 locator includes a GT-80 generator and a PT-12 receiver. The principles of working with locators of the “Stalker” series can be found in educational films:

General features of the Stalker 80-12 locator:
  • A simple and understandable process for searching for underground communications;
  • Remote control of the GT-80 generator via the GSM network;
  • 33 kHz frequency for contactless transmission of the generator signal into communication
  • Search range - up to 10 km at a depth of up to 6
  • “RADIO” frequency (passive) for searching a route without a generator;
  • Non-contact transmission of a search signal using transmitting clamps KI-50 or KI-100.
On backorder
+

79 800.00 

Measurement of the resistance of grounding elements, metal connections, continuity of protective conductors using a two-, three- or four-wire method.

Measurement of soil resistivity.

Measuring the resistance of a single grounding conductor in a multi-element grounding system without disconnecting it using measuring clamps (KTI-20/1 or KTI-20/2).

Measurement of the resistance of grounding elements without the use of auxiliary electrodes (GOST R 50571.16) using two clamps (KP-20/1 and KTI-20/1 or KP-20/1 and KTI-20/2).

AC current measurement without breaking the circuit.

Measurement of AC voltage (noise).

On backorder
+

166 104.00 

The "Stalker 75-12" route finder is designed to determine the planned position and depth of communications, and survey areas of the area before carrying out excavation work.

The delivery package for the Stalker 75-12 locator includes a GT-75 generator and a PT-12 receiver.

General features of the Stalker 75-12 locator:

  • A simple and understandable process for searching for underground communications;
  • Search range - up to 10 km at a depth of up to 6 m;
  • “RADIO” frequency (passive) for searching a route without a generator;
  • Non-contact transmission of a search signal using transmitting clamps KI-50.
On backorder
+

241 974.00 

The route finder "Stalker 80-14" (Li-Ion) is designed to determine the planned position and depth of communications, places of damage to the insulation of pipelines and cables with further cartographic analysis.

The delivery package for the Stalker 80-14 locator includes a GT-80 generator and a PT-14 receiver (Li-Ion)

The principles of operation of the Stalker series locators with high-precision GPS RTK tablet PrinCe LT700H can be found in the training film https://youtu.be/ixbdZwx_-n8

General features of the Stalker 80-14 locator:

  • “Compass” function - schematic display of communications on the receiver display;
  • tracking and coordinating location in a worldwide coordinate system;
  • communication with a computer via Bluetooth, memory for 10,000 measurements;
  • High-precision positioning (up to 1 cm) together with GPS RTK – PrinCe LT700H tablet;
  • the ability to use a smartphone instead of an external GPS/GLONASS module;
  • for gas services, ECP frequencies are separately allocated for operation without a generator;
  • the Stalker 80-14 locator will automatically display the depth and current strength (even in passive modes);
  • remote control of the generator via the GSM network;
  • frequency 33 kHz for contactless supply of the generator signal to communication;
  • search for communications at a depth of up to 10 m and a distance of up to 10 km from the generator connection point;
  • the presence of five operating frequencies and adjustable output power of the GT-80 generator (from 10 to 80 W). This generator is included in the set of Stalker defect detection systems: 80-24, 80-14, 80-12;
  • PT-14 receiver menu in Russian and English.
No products with the selected options in stock

199 866.00 

The Stalker 75-14 route finder is designed to determine the planned position and depth of communications, places of damage to the insulation of pipelines and cables with further cartographic analysis.

The delivery package for the Stalker 75-14 locator includes a GT-75 generator and a PT-14 receiver with a built-in GPS/GLONASS module (Li-Ion)

The principles of operation of the Stalker series locators with high-precision GPS RTK tablet PrinCe LT700H can be found in the training film https://youtu.be/ixbdZwx_-n8

General features of the Stalker 75-14 locator:

  • “Compass” function - schematic display of communications on the receiver display;
  • tracking and coordinating location in a worldwide coordinate system;
  • communication with a computer via Bluetooth, memory for 10,000 measurements;
  • built-in GPS/GLONASS module;
  • High-precision positioning (up to 1 cm) together with GPS RTK – PrinCe LT700H tablet;
  • the ability to use a smartphone instead of an external GPS/GLONASS module for gas services, ECP frequencies are separately allocated for operation without a generator;
  • the Stalker 80-14 locator will automatically display the depth and current strength (even in passive modes);
  • remote control of the generator via the GSM network;
  • frequency 33 kHz for contactless supply of the generator signal to communication;
  • search for communications at a depth of up to 10 m and a distance of up to 10 km from the generator connection point;
  • the presence of five operating frequencies and adjustable output power of the GT-75 generator (from 10 to 75 W). This generator is included in the set of Stalker defect detection systems: 75-24, 75-14, 75-12;
  • PT-14 receiver menu in Russian and English.
On backorder
+

125 400.00 

Measurement of the resistance of grounding elements, metal connections, continuity of protective conductors using a two-, three- or four-wire method.

Measurement of soil resistivity.

Measuring the resistance of a single grounding conductor in a multi-element grounding system without disconnecting it using measuring clamps (KTI-20/1 or KTI-20/2).

Measurement of the resistance of grounding elements without the use of auxiliary electrodes (GOST R 50571.16) using two clamps (KP-20/1 and KTI-20/1 or KP-20/1 and KTI-20/2).

AC current measurement without breaking the circuit.

Measurement of AC voltage (noise).

On backorder
+

156 630.00 

Locator "Stalker 15-14" - fast and accurate search for telephone, power cables and other communications, identification of coating defects and depth, followed by mapping.

The delivery package for the Stalker 15-14 locator includes a GT-15 generator and a PT-14 receiver (Li-Ion).

On backorder
+

99 900.00 

Measurement of the resistance of grounding elements, metal connections, continuity of protective conductors using a two-, three- or four-wire method.

Measurement of soil resistivity.

Measuring the resistance of a single grounding conductor in a multi-element grounding system without disconnecting it using measuring clamps (KTI-20/1 or KTI-20/2).

Measurement of the resistance of grounding elements without the use of auxiliary electrodes (GOST R 50571.16) using two clamps (KP-20/1 and KTI-20/1 or KP-20/1 and KTI-20/2).

AC current measurement without breaking the circuit.

Measurement of AC voltage (noise).

On backorder
+

36 300.00 
Multifunctional portable digital measuring device designed for diagnostics of insulation condition. The megohmmeter allows you to measure insulation...
In stock
+

Contact us for a price
The operation of the wattmeter is based on the principle of converting the power of high-frequency/microwave signals into thermal energy with subsequent...
In stock

69 144.00 

The volt-ampere phase meter RS-30 is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current-measuring clamps is performed using a quick-release Push-Pull connection. The volt-ampere phase meter RS-30 is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

On backorder
+

49 000.00 
B5 - 71 KIP is a laboratory DC power supply. The device is designed to supply radio and electrical devices with standardized characteristics,...
In stock
+

68 310.00 
The B5-107 DC pulse power supply is designed to reproduce the output stabilized voltage and current with wide adjustment limits when used for the...
In stock
+

10 576.00 

EMD-MINI – 004 S ELHART frequency converter (0.4 kW, 2.5 A, 220 V, built-in PID controller, 4 discrete inputs (NPN), 1 discrete output (NO relay, 250 V, 3 A), 1 analog input 4-20 mA / 0-10 V, rotary frequency converter, RS-485 Modbus RTU, DIN rail mounting), EMD-MINI series

In stock
+

Minimum quantity for "EMD-MINI – 004 S" is 1.


10 937.00 

EMD-MINI – 007 S ELHART frequency converter (0.75 kW, 5 A, 220 V, built-in PID controller, 4 discrete inputs (NPN), 1 discrete output (NO relay, 250 V, 3 A), 1 analog input 4-20 mA / 0-10 V, rotary frequency converter, RS-485 Modbus RTU, DIN rail mounting), EMD-MINI series

In stock
+

Minimum quantity for "EMD-MINI – 007 S" is 1.


13 189.00 

EMD-MINI – 004 T ELHART frequency converter (0.4 kW, 1.5 A, 380 V, built-in PID controller, 4 discrete inputs (NPN), 1 discrete output (NO relay, 250 V, 3 A), 1 analog input 4-20 mA / 0-10 V, rotary frequency converter, RS-485 Modbus RTU, DIN rail mounting), EMD-MINI series

In stock
+

Minimum quantity for "EMD-MINI – 004 T" is 1.


16 035.00 

EMD-MINI – 022 S ELHART frequency converter (2.2 kW, 11 A, 220 V, built-in PID controller, 4 discrete inputs (NPN), 1 discrete output (NO relay, 250 V, 3 A), 1 analog input 4-20 mA / 0-10 V, rotary frequency converter, RS-485 Modbus RTU, DIN rail mounting), EMD-MINI series

In stock
+

Minimum quantity for "EMD-MINI – 022 S" is 1.


150 702.00 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

On backorder
+

191 070.00 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

On backorder
+

11 695.00 

EMD-MINI – 015 S ELHART frequency converter (1.5 kW, 7 A, 220 V, built-in PID controller, 4 discrete inputs (NPN), 1 discrete output (NO relay, 250 V, 3 A), 1 analog input 4-20 mA / 0-10 V, rotary frequency converter, RS-485 Modbus RTU, DIN rail mounting), EMD-MINI series

In stock
+

Minimum quantity for "EMD-MINI – 015 S" is 1.


94 260.00 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

On backorder
+

116 148.00 

State register number 62558-15, ссылка на сайт.

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

On backorder
+

81 702.00 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

On backorder
+

106 818.00 

State register number 62558-15, link to the website

The calibration interval is 24 months.

The RS-30 volt-ampere phase meter is one of the main devices for taking vector diagrams and setting up relay protection and automation systems by relay service specialists, and is also used to check metering groups and measure network parameters. The device's operation according to the "Star", "Triangle" and "2-phase" (isolated) connection schemes makes it universal for taking measurements in power engineering, energy supervision, communications, railways, housing and communal services enterprises and other industries. Three types of clamps of different ranges (depending on the selected configuration) allow measuring current from 0.0030 A to 3 kA. The connection of current measuring clamps is performed using a quick-release Push-Pull connection. The RS-30 volt-ampere phase meter is equipped with magnetic holders, which allows, if necessary, to quickly attach the device to steel surfaces, including those with paint and varnish coatings.

On backorder
+

13 844.00 

EMD-MINI – 007 T ELHART frequency converter (built-in PID controller, 4 discrete inputs (NPN), 1 discrete output (NO relay, 250V, 3A), 1 analog input 4-20mA/0-10V, rotary frequency setter, RS-485 Modbus RTU, DIN rail mounting), EMD-MINI series

In stock
+

Minimum quantity for "EMD-MINI – 007 T" is 1.