No items found matching the search criteria
₽ – ₽
Minimum quantity for "PIV-S-D-14.220AC" is 1.
EMD – MINI-075 T ELHART frequency converter (7.5 kW, 17.5 A, 380V, inclusive PID controller, 4 discs output (NPN), 1 disc. output (relay ON, 250V, 3A),1 analog output 4-20mA/0-10V, rotary frequency sensor, RS-485 Modbus RTU), EMD-MINI series
Minimum quantity for "EMD-MINI – 075 T" is 1.
The "Stalker 80-12" route finder is designed to determine the planned position and depth of communications, and survey areas of the area before carrying out excavation work.
The delivery package for the Stalker 80-12 locator includes a GT-80 generator and a PT-12 receiver. The principles of working with locators of the “Stalker” series can be found in educational films:
ASV-W-050-SS080-U Valve with pneumatic actuator, stainless steel, welded DIN 11850 series 2, 2/2 NC, DN 50, T=(-10...+180)C, Punder disk=(0…8 bar), pneumatic actuator 80 mm single-acting (port 1/4'')
Minimum quantity for "ASV-W-050-SS080-U" is 1.
PIV-S-AP-38 Pneumatic distribution valve 5/2, G 3/8'' (exhaust G 1/4''), 1.5...8 bar, pneumatic control G 1/8
Minimum quantity for "PIV-S-AP-38" is 1.
EMD-VL – 0015 S ELHART frequency converter, vector series (1.5kW, 7A, 220V, vector and U/F control, removable remote control, integrated PID controller, RS-485 Modbus RTU), EMD-VL series
Minimum quantity for "EMD-VL – 0015 S" is 1.
Minimum quantity for "PIV-S-E-18.220AC" is 1.
Minimum quantity for "PNA-DA-092" is 1.
Minimum quantity for "PIV-S-B-18.220AC" is 1.
EMD-VL – 0004 S , vector series (0.4kW, 2.5A, 220V, vector and U/F control, removable remote control, integrated PID controller, RS-485 Modbus RTU), EMD-VL series
Minimum quantity for "EMD-VL – 0004 S" is 1.
Minimum quantity for "EPR3-9-G12-4200" is 1.
Minimum quantity for "PNA-DA-160" is 1.
ASV-W-032-SS063 Valve with pneumatic actuator, stainless steel, welded DIN 11850 series 2, 2/2 NC, DN 32, T = (-10 ... + 180) C, P above disk = (0 ... 16 bar, 0 ... 7 bar at P control = 5 bar), pneumatic actuator 63 mm single-acting (port 1/8 '')
Minimum quantity for "ASV-W-032-SS063" is 1.
Minimum quantity for "PIV-S-A-18.220AC" is 1.
PIV-S-CP-14 Pneumatic distribution valve 5/2 bistable, G 1/4'', 1.5...8 bar, pneumatic control G 1/8
Minimum quantity for "PIV-S-CP-18" is 1.
Minimum quantity for "PIV-S-B-38.24DC" is 1.
Minimum quantity for "PIV-S-A-14.12DC" is 1.
Minimum quantity for "PIV-S-C-38.220AC" is 1.
EMD-VL – 0022 S ELHART frequency converter, vector series (2.2kW, 11A, 220V, vector and U/F control, removable remote control, built-in PID controller, 1 expansion card slot, RS-485 Modbus RTU), EMD-VL series
Minimum quantity for "EMD-VL – 0022 S" is 1.
Minimum quantity for "PIV-S-A-38.220AC" is 1.
PTE5000C-004-G1/2-C Pressure sensor 0...4 bar, accuracy 0.5%, output 4...20 mA, G1/2 external thread, power supply 10...30 V DC, -20..+100 deg C
Minimum quantity for "PTE5000C-004-G1/2-C" is 1.
Minimum quantity for "PNA-DA-210" is 1.
ASV-W-040-SS063 Valve with pneumatic actuator, stainless steel, welded DIN 11850 series 2, 2/2 NC, DN 40, T=(-10...+180)C, Pover disk=(0...14 bar, 0...5 bar at Pcontrol=6 bar), pneumatic actuator 63 mm single-acting (port 1/8'')
Minimum quantity for "ASV-W-040-SS063" is 1.
Measurement of the resistance of grounding elements, metal connections, continuity of protective conductors using a two-, three- or four-wire method.
Measurement of soil resistivity.
Measuring the resistance of a single grounding conductor in a multi-element grounding system without disconnecting it using measuring clamps (KTI-20/1 or KTI-20/2).
Measurement of the resistance of grounding elements without the use of auxiliary electrodes (GOST R 50571.16) using two clamps (KP-20/1 and KTI-20/1 or KP-20/1 and KTI-20/2).
AC current measurement without breaking the circuit.
Measurement of AC voltage (noise).
1901R-ABNF016-250-24DC Solenoid valve, brass, 1" (25 mm), 2/2 NO, -10°C...+80°C; 0.5...12 bar, 24 V DC, floating membrane design, coil with moisture protection (coil type 4)
Minimum quantity for "1901R-ABNF016-250-24DC" is 1.