The "Stalker 15-24" locator is a fast and accurate search for telephone, power cables and other communications, identification of coating defects and depth of occurrence, followed by mapping.
The Stalker 15-24 locator is supplied with a GT-15 generator and a PT-24 receiver with a built-in GPS/GLONASS module
Менструальная чаша из 100% медицинского силикона. Объем 15 мл. (размер S).
Minimum quantity for "Menstrual cup red 15 ml. size S" is 1.
The "Stalker 15-14" locator is a fast and accurate search for telephone, power cables and other communications, identification of coating defects and depth of occurrence, followed by mapping.
The Stalker 15-14 locator is supplied with a GT-15 generator and a PT-14 receiver with a built-in GPS/GLONASS module (Li-Ion)
Измерение полного сопротивления петли «фаза-нуль» и «фаза-фаза» с вычислением активного и реактивного сопротивлений.
Вычисление прогнозируемого тока короткого замыкания петли «фаза-нуль» и «фаза-фаза», приведенного к напряжениям сети 220/380 В, 230/400 В или 240/415 В.
Измерение параметров устройств защитного отключения (УЗО) общего и селективного типов, находящихся под напряжением, при следующих параметрах дифференциального тока:
- для типов АС, А и В на синусоидальном токе с возможностью установки начальной фазы тока 0 º и 180 º;
- для типов А и В на пульсирующем постоянном (однополупериодном) токе, на пульсирующем постоянном токе с углом задержки фазы тока 90 º и 135 º с возможностью установки полярности тока.
Измерение напряжения переменного тока.
Измерение напряжения прикосновения при протекании номинального дифференциального тока УЗО (требование ГОСТ IEC 61557-6-2013);
Измерение сопротивления постоянному току (металлосвязь).
Межповерочный интервал 2 года
The device is designed to test residual current devices (RCDs) of AC, A types. The RCD type and its rated differential current are set manually in the device. All types of RCDs that do not have an operational amplifier with threshold values can be checked using the device offline, for example, when buying, without connecting voltage to the mains.
The device is powered by five 1.5 V AA batteries.
Operating temperature range from -15 to +55 0C.
Calibration interval 2 years.
The device is designed to test residual current devices (RCDs) of AC, A, B types. The RCD type and its rated differential current are set manually in the device. All types of RCDs that do not have an operational amplifier with threshold values can be checked using the device offline, for example, when buying, without connecting voltage to the mains. There is a function for measuring the resistance of the phase-zero loop from 0.4 to 60 ohms. PZO-510 is equipped with magnetic holders, which allows, if necessary, to quickly mount the device on steel surfaces, including those with paint and varnish coatings.
The instrument is powered by a NI-MH 6 V 2A/H battery or five 1.5 V AA batteries.
Using the IFN-300 device, it is possible to measure the resistance of the "phase-zero", "phase-phase" loop and the transition resistance of contact connections. Using the data obtained, it is possible to identify malfunctions in group lines and carry out a set of measures in a short time to avoid serious accidents and fires.
Measurement of the "phase-zero" loop is carried out during acceptance testing of equipment at the request of controlling organizations or periodically - once every 3 years.When measuring the loop resistance "phase-zero", "phase-phase", the device simultaneously measures the active, reactive and impedance of the loop, and also calculates the predicted short-circuit current without disabling the line protection. This is necessary to check the correctness of the set nominal value of the short-circuit protection element (circuit breaker or fuse) and determine the timely operation of this protection. The body of the device is equipped with magnetic holders, which allows, if necessary, to quickly mount the device on steel surfaces, including those with paint and varnish coatings.