No items found matching the search criteria
₽ – ₽
Minimum quantity for "PIV-S-B-14.24AC" is 1.
VBE-S-B-18.220AC Distribution valve 3/2-NC, 1/8", direct acting, 0...8 bar, -5...+60°C, ~220 V 50-60 Hz, coil type B, connected in blocks with a common pressure supply
Minimum quantity for "VBE-S-B-18.220AC" is 1.
PTE5000C-010G 1/4-C Pressure sensor 0.10 bar, accuracy 0.5%, output 4.20 mA, G1/4 male thread, power supply 10.30 V DC, -20..+100 deg C
Minimum quantity for "PTE5000C-010-G1/4-C" is 1.
Minimum quantity for "PNA-DA-105" is 1.
Using the IFN-300 device, it is possible to measure the resistance of the "phase-zero", "phase-phase" loop and the transition resistance of contact connections. Using the data obtained, it is possible to identify malfunctions in group lines and carry out a set of measures in a short time to avoid serious accidents and fires.
Measurement of the "phase-zero" loop is carried out during acceptance testing of equipment at the request of controlling organizations or periodically - once every 3 years.When measuring the loop resistance "phase-zero", "phase-phase", the device simultaneously measures the active, reactive and impedance of the loop, and also calculates the predicted short-circuit current without disabling the line protection. This is necessary to check the correctness of the set nominal value of the short-circuit protection element (circuit breaker or fuse) and determine the timely operation of this protection. The body of the device is equipped with magnetic holders, which allows, if necessary, to quickly mount the device on steel surfaces, including those with paint and varnish coatings.
Minimum quantity for "PIV-S-A-14.24DC" is 1.
Pressure sensor 0...4 bar, accuracy 0.5%, output 4...20 mA, G1/4 male thread, power supply 10...30 V DC, -20..+100 deg C
Minimum quantity for "PTE5000C-004-G1/4-C" is 1.
PTE5000C-006-G1/2-C Pressure sensor 0...6 bar, accuracy 0.5%, output 4...20 mA, G1/2 external thread, power supply 10...30 V DC, -20..+100 deg C
Minimum quantity for "PTE5000C-006-G1/2-C" is 1.
PTE5000C-010-M20-C Pressure sensor 0...10 bar, accuracy 0.5%, output 4...20 mA, M20*1.5 male thread, power supply 10...30 V DC, -20..+100 deg C
Minimum quantity for "PTE5000C-010-M20-C" is 1.
1901R-KDNB025-025-24DC Solenoid Valve, Brass, 1/4” (2.5 mm), 2/2 NC, -10°C...+80°C; 0...25 bar, 24B= (coil type 4)
Minimum quantity for "1901R-KDNB025-025-24DC" is 1.
PTE5000C-016-M20-C 0...16 bar, accuracy 0.5%, output 4...20 mA, M20*1.5 male thread, power supply 10...30 V DC, -20..+100 deg C
Minimum quantity for "PTE5000C-016-M20-C" is 1.
1901R-ABNF016-250-220AC Solenoid valve, brass, 1" (25 mm), 2/2 NO, -10°C...+80°C; 0.5...16 bar,floating membrane design, coil with moisture protection (coil type 4)
Minimum quantity for "1901R-ABNF016-250-220AC" is 1.
1841R-KBLD040-120-24DC High pressure solenoid valve, brass, 1/2” (12 mm), 2/2 NC, -10°C...+100°C; 0,5...40 bar, 55 l/min, diaphragm: brass+polyurethane, 24VDC, for water and air, PET container blowing (coil type 4).
Minimum quantity for "1841R-KBLD040-120-24DC" is 1.
PTE5000C-004-M20-C 0...4 bar, accuracy 0.5%, output 4...20 mA, M20*1.5 male thread, power supply 10...30 V DC, -20..+100 deg C
Minimum quantity for "PTE5000C-004-M20-C" is 1.
Minimum quantity for "PNA-SA-105" is 1.
Minimum quantity for "PIV-N-A-14 (N).220AC" is 1.
Minimum quantity for "PIV-S-B-18.24AC" is 1.
Minimum quantity for "PNA-DA-063" is 1.
1901R-KBNF016-250-24DC Solenoid valve, brass, 1" (25 mm), 2/2 NC, -10°С...+80°С; 0.5…12 bar, 24V=, floating diaphragm design, moisture-proof coil (coil type 1, spare parts type A)
Minimum quantity for "1901R-KBNF016-250-24DC" is 1.
Minimum quantity for "PIV-S-A-18.24DC" is 1.
1901R-KBNF016-250-220AC Solenoid valve, brass, 1" (25 mm), 2/2 NC, -10°C...+80°C; 0.5...16 bar, 220V 50-60Hz, floating membrane design, coil with moisture protection (coil type 1, spare parts type A)
Minimum quantity for "1901R-KBNF016-250-220AC" is 1.
PIV-S-BP-18 Pneumatic distribution valve 3/2-NC, G 1/8'', 1.5...8 bar, pneumatic control G 1/8"
Minimum quantity for "PIV-S-BP-18" is 1.
1901R-ABNF016-250-24DC Solenoid valve, brass, 1" (25 mm), 2/2 NO, -10°C...+80°C; 0.5...12 bar, 24 V DC, floating membrane design, coil with moisture protection (coil type 4)
Minimum quantity for "1901R-ABNF016-250-24DC" is 1.
PIV-S-CP-14 Pneumatic distribution valve 5/2 bistable, G 1/4'', 1.5...8 bar, pneumatic control G 1/8
Minimum quantity for "PIV-S-CP-18" is 1.
PTE5000C-004-G1/2-C Pressure sensor 0...4 bar, accuracy 0.5%, output 4...20 mA, G1/2 external thread, power supply 10...30 V DC, -20..+100 deg C