Ground resistance meter IS-20/1 with clamps KTI-20/1

Write a review
79 800.00 
134324
On backorder
+

Measurement of the resistance of grounding elements, metal connections, continuity of protective conductors using a two-, three- or four-wire method.

Measurement of soil resistivity.

Measuring the resistance of a single grounding conductor in a multi-element grounding system without disconnecting it using measuring clamps (KTI-20/1 or KTI-20/2).

Measurement of the resistance of grounding elements without the use of auxiliary electrodes (GOST R 50571.16) using two clamps (KP-20/1 and KTI-20/1 or KP-20/1 and KTI-20/2).

AC current measurement without breaking the circuit.

Measurement of AC voltage (noise).

Specifications:

1. Earth resistance measurement

Resistance measurement ranges

Permissible value of resistance in connection circuits, no more

Limits of permissible basic error of resistance measurements for the four-wire measurement method

current

Т1 - Т2

potential

P1 - P2

1 to 999 mΩ

30 ohm

40 kOhm

± (0.03×R + 3 units)

0.01 to 9.99 ohms

1 kOhm

0.1 to 99.9 ohms

10 kOhm

from 1 to 999 ohm

40 kOhm

1 to 9.99 kOhm

Maximum interference voltage amplitude for resistances

up to 999 mΩ

no more than 12 V

1.00 ohm to 9.99 k ohm

no more than 24 V

Measuring voltage and current

no more than 42 V and 250 mA, frequency 128 Hz

2. Earth resistance measurement with one clamp

Resistance measurement ranges

Permissible value of resistance in connection circuits, no more

Limits of permissible basic absolute error of resistance measurements with one clamp for a four-wire measurement method

current

T1 - T2

potential

P1 - P2

1 to 999 mΩ

30 ohm

40 kOhm

±( 0.05×R+ R2 ∕ (300×Rtot)+3 mu)

0.01 to 9.99 ohms

1 kOhm

0.1 to 99.9 ohms

from 1 to 999 ohm

0.01 to 9.99 kΩ

Measuring tongs grip diameter: KTI-20/1

KTI-20/2

50 mm

80 mm

3. Earth resistance measurement with two clamps

Resistance measurement ranges

Limits of permissible basic absolute error of resistance measurements

0.03 to 9.99 ohm

± (0.1×R + 3 units)

10.0 to 99.9 ohms

± (0.15×R + 3 units)

4. Measurement of the amplitude value of AC voltage 50 Hz

Measurement range

from 1 to 300 V

Limits of permissible basic absolute measurement error

± (0.05×U + 3 units)

5. Measurement of AC current with a frequency of 50 Hz using measuring clamps

Measurement range

from 1 to 250mA

0.25 to 2.50 A

Limits of permissible basic absolute measurement error

± (0.05×I + 3 units)

Additionally:

Power supply - Ni-MH battery 6 V, 2000 mAh or 5 AA batteries;

Operating temperature range - from -15 ºС to +50 ºС;

Degree of protection of the body - IP54;

Overvoltage category - CAT IV 300 V.

ООО «ТД «Радио-Сервис» / “Radio-Service”, JSC.

The company "Radio-Service" offers a wide range of electrical measuring instruments for route-finding equipment of various prices, used in various fields of activity. The good quality and affordable price of our products have allowed us to take a strong position in the Russian market.

The instruments we produce include:

  • megaohmmeters;
  • ground resistance meters;
  • loop resistance meters;
  • RCD parameters meters;
  • voltammeters;
  • route finders;
  • marker detectors.

No reviews found