Household gas meters SGB-1.8 are designed for measuring the volume of liquefied hydrocarbon gas in accordance with GOST 20448-90 and natural gas in accordance with GOST 5542-87 when accounting for gas consumption by individual consumers.
Gas flow measurement range (m3/h) - from 0.03 to 1.8.
The kit includes a nut thread 1/2 (nut-nipple)
Calibration interval - 12 years.
Check is fresh. Within 6 months.
Certificate of Conformity: Russian Federation and Republic of Belarus
Counter passport:
RF - YES
Republic of Belarus - NO
The principle of operation of household gas meters SGB-1.8 is based on the conversion of the volume of gas that has passed through the meter into a proportional number of electrical impulses using a jet oscillation generator, followed by counting on an electronic unit for measuring gas volume.
Counters consist of the following main units:
- a housing with a jet generator located in it, a piezoelectric element and inlet and inlet connecting pipes;
- electronic block;
- battery;
- two plastic pads.
Counters have a reporting device on a liquid crystal display.
Metrological and technical characteristics
Nominal diameter, mm
15
Range of measured flow rates, m3/h
from 0.03 to 1.8
The limits of the permissible basic relative error of the meter, %, are equal in the flow rate range:
- from Q min to 0.2 Q max
- from 0.2 Qmax to Qmax
±2.5
±1.5
Limits of permissible additional relative error caused by the deviation of the ambient air temperature from normal within the operating temperature range for every 10 °C temperature change, %
±0.5
The smallest division value of the reporting device, m3
0.001
Reading device capacity, m3, not less than
99999.999
Supply voltage, V
3.6
Overall dimensions, mm, no more
110x66x55
Weight, kg, no more
0.3
Average service life, years, not less
24
Mean time between failures, h, not less than
120000
Terms of Use:
- ambient air temperature, °C
- relative humidity, %
- atmospheric pressure, kPa
from minus 10 to plus 50
from 30 to 80
from 84 to 106.7
Solving complex production and technical problems in the field of heating and ventilation. Making high technology accessible.
- Accredited design engineers will solve the design issue for you (We work with the largest design institutes)
- A professional installation and maintenance service with many years of experience will help you perform construction and installation work, make commissioning, installation supervision.
Today we have experience in deliveries to the most remote regions of Russia and the CIS by land, air and sea transport.
No reviews found